Inf iRay AT31F/AT61F Online Temperature Measurement Thermal Camera User Manual

Inf iRay AT31F/AT61F Online Temperature Measurement 
Thermal Camera User Manual

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera User Manual

www.iraytek.com

Legal Disclaimer

1.1 Legal Disclaimer

The thermal cameras manufactured by IRAY TECHNOLOGY are warranted for a period of two-year and the accessories are warranted for a period of three-month form the delivery date of the original purchase, provided such products have been under normal storage, use and maintenance.
This warranty extends only to the original purchaser and is not transferable. It is not applicable to any product that has be subjected to misuse, neglect, accident or abnormal conditions of operation.
In the case of a defect in a product covered by this warranty the product must not be further used or maintained in order to prevent additional damage. The purchaser shall promptly report any defect to IRAY TECHNOLOGY or this warranty will not apply.
IRAY TECHNOLOGY will, at its option, repair or replace any such defective product free of charge if, upon inspection, the product or accessories prove to be defective, the user can contact with after-sales service department of IRAY
TECHNOLOGY within the said warranty period.

1.2 Copyright

©IRay Technology Co., Ltd. 2021. All rights reserved worldwide. All contents in this manual, including words, pictures, images, etc., belong to IRAY
TECHNOLOGY CO., LTD. (Hereinafter referred to as “THE COMPANY” or “IRAY TECHNOLOGY”). No part of the manual, in whole or part, may be copied, photocopied, translated, or transmitted without the prior written permission of IRAY TECHNOLOGY.
This manual is used as a guide. The photos, graphics, diagrams and illustrations provided in the manual are only used to explain, which may be different from the specific product. The real product shall prevail. We try our best to make sure the contents in this manual are accurate. We do not provide any representations or warranties in this manual.
IRAY TECHNOLOGY reserve the right to update the manual. If you need the latest version of this manual, please contact us. It is recommended that you use this manual with the guidance of professionals.

1.3 Quality Assurance

The Quality Management System under which these products are developed and manufactured has been certified in accordance with the ISO 9001 standard.
We reserve the right to make changes and improvements on any of the products without prior notice.

Safety Information

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Safety Information

Notice to user

3.1 Calibration

IRAY TECHNOLOGY recommends that you verify your calibration yearly in order to ensure accuracy. You can verify the calibration through IRAY TECHNOLOGY or third-party organizations.

3.2 Accuracy

For very accurate results, we recommended that you wait 30 minutes after you have started the camera before measuring a temperature.

3.3 Video Teaching

You can search for mount and use videos from our website.

3.4 Documentation Updates

Our manuals are updated several times per year, and we also issue product-critical notifications of changes on a regular basis. Please visit our website to access the latest manuals and notifications.

Customer Help

4.1 FAQ

You can find answers to FAQ about this model on the service support page of our official website.

4.2 Download

You can download the following contents from our website:

  • Product Documentation
  • Client Software
  • Video Teaching Courses

Product Introduction

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Product Introduction

Main Features:

  • Compact Size
  • Quick Installation
  • Several optional lenses
  • I/O Alarm
  • Simultaneous output of temperature data and image data

Typical Applications:

  • Power detection
  • Industrial detection
  • Environmental Monitoring
  • Fire Warning

Product Figure and Explanation

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Product Figure and Explanation

Table 6.1 Explanation of Product Appearance

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 6.1 Explanation of Product Appearance

Product Models Reference

Table 7.1 Product Models List

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 7.1 Product Models List

E.G.:AT31F3X(AT21F-3-X) stands for AT31F with 9.7mm lens.

Lens Parameters

Table 8.1 AT31F Lens Parameters

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 8.1 AT31F Lens Parameters

Table 8.2 AT61F Lens Parameters

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 8.2 AT61F Lens Parameters

Quick Start Guide

Please follow the steps:

  1. Install IRT_VMS if the thermal camera is with other networking equipments, and IRT_TAS_AT can be installed on a single thermal camera for temperature measurement and analysis. The software may have version updates. Please refer to the actual version. It is recommended that the computer configuration for installing the software meet the following conditions: i5-9500T and above CPU, 8G and above memory, 64-bit win10 system, and supporting Gigabit network.
  2. Connect the thermal camera, power supply and computer.
  3. Set the computer configurations according to the software instructions for IRT_VMS_User Manual or IRT_TAS_AT_User Manual.
  4. Double-click the client icon, enter the correct user name and password, and click login to start the client.
  5. Select the IP on the client homepage, and add the module number you want to preview to the PC preview interface. If the thermal camera is successfully connected, you can start imaging and monitoring with the thermal camera.
  6. The 232 transmission between the computer and the thermal camera can be realized through the RS232 interface on the cable.
  7. The 485 transmission between the thermal camera and the PT can be realized through the RS485 interface on the cable to contron the PT.
  8. The ALARMIN interface on the cable can be used to manually input signals to trigger the alarm.
  9. The I/O alarm output of the thermal camera can be realized through the ALARMOUT interface on the cable. Non-alarm information remains high, and becomes low when there is alarm information. After the alarm disappears, it will continue to be maintained for 30 seconds and then return to high level.

Product and Accessories List

Table 10.1 Product and Accessories List

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 10.1 Product and Accessories List

Technical Data

11.1 AT31F

Table 11.1.1 AT31F Performance Parameters

 

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 11.1.1 AT31F Performance Parameters

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 11.1.1 AT31F Performance Parameters 2

11.2 AT61F

Table 11.2.1 AT61F Performance Parameters

 

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 11.2.1 AT61F Performance Parameters

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 11.2.1 AT61F Performance Parameters 2

Mechanical Drawings

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Mechanical Drawings

Common Troubleshooting

Table 13.1 Product Common Troubleshooting

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Table 13.1 Product Common Troubleshooting

Cleaning Thermal Camera

14.1 Camera Housing, Cables and Other Items

14.1.1 Liquids

One of the following liquids can be used.

  • Warm water
  • Mild detergent solution

14.1.2 Cleaning Tools

A soft cloth

14.1.3 Cleaning Procedure

Please follow this procedure:

  1. Soak a soft cloth in the liquid.
  2. Twist the cloth to remove excess liquid.
  3. Clean the camera parts with the cloth.
14.2 Cleaning Infrared Lens

14.2.1 Liquids

One of the following liquids can be used.

  • Commercial lens cleaning liquid with more than 30% isopropyl alcohol.
  • 96% ethyl alcohol (C2H5OH)

14.2.2 Cleaning Tools

Dustless cloth, cotton wool

14.2.3 Cleaning Procedure

Please follow this procedure (Take dustless cloth as an example).

  1. Soak the dustless cloth in the liquid.
  2. Gently wipe the lens with the dustless cloth

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Gently wipe the lens with the dustless cloth

Terms and Definitions

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Terms and Definitions

Appendix A Emissivity of Common Materials

 

Inf iRay AT31F AT61F Online Temperature Measurement Thermal Camera - Appendix A Emissivity of Common Materials