VEVOR SPP2200 Swimming Pool Pump User Manual

VEVOR SPP2200 Swimming Pool Pump User Manual

VEVOR SPP2200 Swimming Pool Pump User Manual

VEVOR SPP2200 Swimming Pool Pump User Manual

VEVOR SPP2200 Swimming Pool Pump User Manual-Model

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

MAIN PARTS

VEVOR SPP2200 Swimming Pool Pump User Manual-Main parts

PARTS

  1. Strainer Cover
  2. 0-Ring,Strainer Cover
  3. Strainer basket
  4. C-clip
  5. Drain Plug
  6. Drain Plug Gasket
  7. Strainer Hosing
  8. 0-Ring, Hosing cover
  9. Screw
  10. Washer
  11. Hosing cover
  12. 0-Ring, Housing
  13. Impeller
  14. Shaft Seal Assembly
  15. Pump Housing
  16. Slinger
  17. Motor
  18. Grounding Terminal

INSTALLATION

READ CAREFULLY AND SAVE THIS INSTRUCTION MANUAL ATTENTION INSTALLER-THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END-USER OF THIS PRODUCT.FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULTIN SERIOUS INJURY.

SAFETY PRECAUTIONS

Read this “Safety Precautions'” before operation.

The below information should not be neglected for the proper use of this product. Your understanding can prevent harm or danger to the user or others.

VEVOR SPP2200 Swimming Pool Pump User Manual-important information

VEVOR SPP2200 Swimming Pool Pump User Manual-Danger

VEVOR SPP2200 Swimming Pool Pump User Manual-Warning

VEVOR SPP2200 Swimming Pool Pump User Manual-Caution

VEVOR SPP2200 Swimming Pool Pump User Manual-installation

Rotate the fan blade before starting-up, check whether the pump rotation is flexible, then unscrew the water-filling plug, fill the pump chamber with clean water from the water iniection hole,then tighten the plug screw after the air has been completely discharged. Set the valve for a smaller water flow when starting-up, and then adjust to your required water flow after water discharging.

VEVOR SPP2200 Swimming Pool Pump User Manual-Water Discharging

Before servicing, all water circulation systems and pump controls must be off position and release all the pressure from the system.

WARNING: This product should be installed and serviced by a qualified pool professional.
This pump is compatible with above-ground pools and spas. Locate the pump as close to the pool and water level as possible. Do not add too many elbow pipes in the plumbing so as to avoid suction reduction. It is highly recommended that the pump be placed in cool, dry places and avoid direct sunlight. Install the pump on a firm, level base or pad to meet all local and national codes.Fasten the pump to a base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base must be solid, level, rigid, and vibration-free.

WARNING: Keep product away from Children.

Use Teflon tape on the thread before screw fittings to pump inlet and outlet ports so as to avoid leakage. Do not over-tighten the fittings.

VEVOR SPP2200 Swimming Pool Pump User Manual-pump controls

VEVOR SPP2200 Swimming Pool Pump User Manual-pump controls

VEVOR SPP2200 Swimming Pool Pump User Manual-pump controls

Accessory:

  1. Manual
  2. 2 pcs of NPT 1-1/2” adaptor
  3. 2 pcs of 48.5mm (ID) adaptor
  4. 1 roll PTFE tape

SPECIFICATIONS

VEVOR SPP2200 Swimming Pool Pump User Manual-Specifications

Make sure that the electrical supply available is suitable for the motor’s voltage, phase, and cycle.

Voltage from the power must be in the range from 90%to 110% of the motor nameplate rated voltage. Otherwise, the motor may overheat and result in overload tripping and reduced component life.

Install, ground, bond, and wire motor in accordance with local or NEC requirements.

The motor should be grounded permanently by connecting the ground terminal to the electrical service ground.

Bond motor to pool structure.Bonding will connect all metal parts within and around the pool with a continuous wire. Bonding reduces the risk of current passing between bonded metal objects, which could potentially cause electrical shock if grounded or shorted.

PRIMING

Fill strainer housing with water to suction pipe level. If water leakage occurs anywhere on the pump or filter, DO NOT start the pump. If no leakage occurs, stand at least 10 feet from the pump and/or filter and proceed with starting the pump.

TROUBLE SHOOTING

MOTOR WILL NOT START

  • Improper or loose wiring connections;, open switches or relays; tripped circuit breakers, GFCI’s, or blown fuses.
  • Manually check rotation of motor shaft for free movement and lack of obstruction.
  • If you have a timer, make sure it is working properly.Bypass it if necessany.

MOTOR SHUTS OFF

  • Undersized wiring:loose connections; etc.
  • Low voltage at motor or power drop(frequently caused by undersized wiring or extension cord use).

MOTOR HUMS BUT DOES NOT START

  • Mechanical binding and electrical overload.
  • Centrifugal switch stuck in the OPEN position.
  • Binding of the motor shaft.

PUMP WON’T PRIME

  • Make sure pump strainer housing is flled with water and the cover O-ring is clean;also, be sure it is properly seated in the cover O-ring groove. Make sure the strainer cover is locked firmly in position and lubricated with’Jack’s 327″.
  • Make sure all suction and discharge valves are fully open and not blocked, that the pool water level is at a proper level and that the skimmer weir is not hung up or stuck on the skinmer wall.
  • Block off to determine if the pump will develop a vacuum.You should have 5″-6″of vacuum at the strainer cover. You may be able to check by removing the skimmer basket and holding your hand over the bottom port with the skimmer full and pump running. If no suction is felt, check for line blockage.

A. If pump develops a vacuum, check for a blocked suction line or dirty strainer basket, and an air leak in the suction piping may be the cause.
B. If the pump does not develop a vacuum and the pump has sufficient “priming water”:

i.  Re-check strainer housing cover and all threaded connections for suction leaks. Check if all hose clamps are tight.
ii. Check voltage to ensure that the motor is rotating at full RPM.
iii. Open housing cover and check clogging or obstruction in suction.Check impeller for debris.
iv. Remove and replace shaft seal only if it is leaking.

TROUBLE SHOOTING(CONTINUED)

LOW FLOW

  • Clogged or restricted strainer or suction line;undersized pool piping.
  • Plugged or restricted discharge line or fiter, valve partially closed (high gauge reading) . How to correct:Backwash strainer as per manufacturer’s instructions;
  • Air leak in suction piping causing rumbling in the pump.Cavitation due to restricted or undersized suction line or leak at any joint, low water level in the pool, and unrestricted discharge return lines.
  • Correct suction condition or throttle return lines, if practical.

NOISY PUMP

  • Vibration due to improper mounting, etc. Put a rubber pad under metal mounting feet.
  • Foreign matter in the pump housing. Loose stones/debris hitting the impeller could be the cause;remove any above.
  • Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine. All seal leaks should be replaced at once.
  • Equipment base vibrating.
  1. Waming-To reduce the risk of injury, user must read instructions manual carefully.
  2. The product complies with relevant standards and regulations. Installation of this device must comply with all applicable regulations, and it should only be operated in well-ventilated areas. Please read the user manual before installing and using this equipment.
  3. This appliance is not intended for use by persons (including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  4. Children shall not play with the appliance.
  5. This appliance is intended to be used in household and similar applications such as:
    -staff kitchen areas in shops, offices and other working environments;
    -farm houses;
    -by clients in hotels, motels and other residential type environments;
    -bed and breakfast type environments.
  6. Please use the product according to the intended use, warn of potential injury from misuse.
  7. Switch off the appliance and disconnect from supply before changing accessories or approaching parts that move in use.
  8. Always disconnect the appliance from the supply if it is left unattended and before assembling, disassembling or cleaning.
  9. WARNING: Only use the supply unit provided with this appliance.
  10. WARNING: Use only an external supply with the following specifications:

<voltage and nature of supply> <power/current of supply>

DANGER: Risk of electric shock! This equipment is used near water.Must be properly grounded and protected by a residual current device (RCD).Never immerse pump, cord or switch in water.

WARNING:
Disconnect all power, lock out and tag out before installation, wiring or maintenance to prevent accidental starting.
Keep body parts away from suction inlet, filter and rotating parts when pump is running to avoid entrapment, entanglement or cutting injury.Children and untrained persons must not install, operate or maintain this equipment.
Pump, piping and filter may become hot during operation. Do not touch to prevent burns.
Close valves, relieve pressure, disconnect power and allow pump to stop completely before service.
Do not use or store near flammable or explosive gases or chemicals.If power cord or components are damaged, they must be replaced by qualified personnel. Do not repair by yourself.

CAUTIONS:
Ensure pump and piping are filled with water before starting. Dry running is strictly prohibited as it will damage seals and pump.
Regularly inspect suction cover, piping, valves and seals for damage, blockage or leakage.
Keep suction inlet clear. Do not cover or block the inlet.
Maintain filter as required to keep it clean and avoid overload.
Disconnect power during thunderstorms to prevent lightning damage.
For pool and water feature circulation only. Not for drinking water, chemicals or flammable liquids.

VEVOR SPP2200 Swimming Pool Pump User Manual-icon