SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide

Lamp / Ballast Guide

QTP 2x20MH/UNV
QTP 1x20MH/UNV SQ
C156
QTP 1x39MH/UNV
QTP 2x39MH/UNV
QTP 1x39MH/UNV SQ
M130; C130
QTP 1x70MH/UNV
QTP 1x70MH/UNV SQ
M98/M139, C98/C139/C143
QTP 1x100MH/UNV
QTP 1x100MH/UNV SLIM
M90, C90, C191

Key System Features

  • Low frequency square wave
  • Suitable for both quartz and ceramic lamps
  • Constant power regulation
  • Universal input voltage
  • High power factor
  • Low harmonic distortion
  • Small size and lightweight
  • UL, FCC
  • End-of-lamp-life shut down
  • Internal IDTP (Insulation Detection Thermal Protector)
  • QUICK 60+® warranty
  • RoHS compliant
    Lead-free solder and manufacturing process

Application Information

SYLVANIA QUICKTRONIC MH
is ideally suited for:

  • Track lighting
  • Downlighting
  • Landscape lighting
  • Retail
  • Hospitality
  • Institutional
  • Commercial

SYLVANIA QUICKTRONIC QTP MH electronic HID (eHID) ballasts feature a state-of-the-art design to deliver performance levels unattainable with standard magnetic lighting systems. These ballasts operate METALARC® and METALARC POWERBALL® Ceramic lamps with exceptional features and benefits, listed below:

Unmatched Energy Efficiency:

  • Ballastsprovidesupto92%efficiency allowing maximum energy savings when compared to magnetic ballasts

New Smaller cases:

  • Mini Slim and Mini Square ballasts are 50% smaller than the standard sized can
  • New smaller sizes allow more flexible fixture designs and applications while maintaining the features and system
    advantages of the standard size ballast

Simple Installation:

  • Installation is simplified by a single piece ballasts that incorporate the ballast, capacitor, ignitor and mounting brackets of conventional systems
  • Two lightweight mounting styles allow for easy assembly in any fixture application (F-case and J-case)

RoHS Compliant: QUICKTRONIC MH ballasts are RoHS compliant and feature lead-free solder and manufacturing process

QUICK 60+® Warranty: Setting the standard for quality, QUICKTRONIC MH ballasts are covered by a QUICK 60+
warranty, the first comprehensive system warranty in the industry

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - Main Product

System Information

SYLVANIA QUICKTRONIC QTP MH electronic HID (eHID) ballasts are perfectly matched with SYLVANIA METALARC® and METALARC POWERBALL® Ceramic lamps to provide optimal system performance. This electronically controlled system delivers several advantages over conventional systems, including improved lumen maintenance and extended photometric life.

Low frequency square-wave:

  • Eliminates acoustic resonance issues typical with high-frequency waveforms (Acoustic resonance issues may cause
    visual flickering, lamp cycling, shortened lamp life, and in extreme cases may result in non-passive failure)
  • Provides a robust approach with respect to acoustic stabilities and is immune to variation in lamp geometry, fill
    chemistry and mercury dose

Superior constant power regulation design:

  • Helps yield consistent light output and color throughout the life of the lamp
  • Provides constant light output during periods of fluctuating supply voltage

End-of-lamp-life shutdown:

  • ·Prevents continuous starting after lamps extinguish which may cause permanent damage to the ballast

Internal IDTP (Insulation Detection Thermal Protector):

  • Affords original equipment manufacturers (OEMs) to remove all external thermal protection devices
  • Reduces wiring complexity and installation time (to maximize the benefits of IDTPs, the ballast must be properly installed – See “installation notes” for details)

SPECIFICATION DATA

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - SPECIFICATION DATA

Installation Notes

  1. Proper ballast mounting must be followed to allow for maximum thermal dissipation:
    a. F can ballast should be mounted with the “feet” side placed tightly against the inside of the fixture.
    b. J can ballast should be mounted with the PEM Stud side placed tightly against the inside of the fixture.
  2. Lamp holders and conductors:
    a. Use minimum 4kV Pulse Rated Lamp holder.
    b. Use minimum 600Vrms/4kV Pulse Rated Wire to lamp.
    c. The red lead must be connected to center terminal of lamp.
    d. Do not connect any lamp lead to neutral or ground.
  3. Grounding:
    a. The ballast case and fixture must always be grounded. The grounding helps assure safety, proper lamp starting, and acceptable EMI/RFI performance. Install ballast in accordance with national and local electrical codes.
  4. Auto shut down function including end-of-lamp-life and thermal protection:
    a. Disconnect power when servicing. Cycle power to reset ballast after auto shutdown.
  5. Control: Do not operate with dimmer or occupancy sensor.
  6.  If connecting the ballast input to 208V or 240V line with two “hot” leads, be sure to wire per NEC code: Re-Mark (re-identify) the ballast white neutral wire to another color (i.e. black). Be sure to simultaneously disconnect all ungrounded line conductors per NEC codes (i.e. switch both hot legs).

More installation considerations are in the QUICKANSWERS section of the Ballast Technology and Specification Guide.

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - Packaging

Professional Series

Performance Guide

Ballast shall be a metal halide SYLVANIA QUICKTRONIC MH electronic ballast with universal input voltage.

Specifications

Voltage Range: ±10% of 120-277V
rated line (108-305V)
Input Frequency: 50/60 Hz
Power Factor: >98%
Low THD: <10%
Starting Temp: -22°F (-30°C) min.
Lamp Frequency: 165 Hz Square Wave
UL Listed, Type 1, Outdoor
Suitable for recessed use
80°C Max. Case Temperature,
Thermally Protected
FCC 47CFR Part 18 Non-Consumer
Sound Rated A
ANSI C62.41 Cat. A Transient Protection
Remote Mounting capability3
Lamp current crest factor: <1.2
RoHS Compliant 4

3 Remote Mounting (max. wire length from ballast case to lamp holder): Typically 6 ft but varies by application. For remote mounting distances up to 15 ft, use #18 AWG minimum 600Vrms/4kV pulse rated wire. Output wires should be enclosedin1/2″metalconduittominimize EMI (electromagnetic interference). Wire and ground ballast, fixture, conduit & lighting system per NEC (National Electrical Code).
4 Complies with European Union Restriction of Hazardous Substances Directive.

System Life / Warranty

QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin.

Packaging: Quantity: 10 pieces per carton Weight: 6 lbs. per carton (0.6 lbs each)

Max. Case Temp.
Measured at
Tc Point Warranty Period
<75°C 5 years
<80°C 3 years

OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com

SPECIFICATION DATA

Catalog # Date Type
Project Prepared by
Comments

Electronic Metal Halide Systems Mini Square and Mini Slim (120-277V)

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - Electronic Metal Halide Systems Universal Voltage SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - Electronic Metal Halide Systems Universal Voltage

Performance Guide
Ballast shall be a metal halide SYLVANIA QUICKTRONIC MH electronic ballast with universal input voltage.

SPECIFICATION DATA

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - SPECIFICATION DATA

Installation Notes

  1. Proper ballast mounting must be followed to allow for maximum thermal dissipation:
    a. F can ballast should be mounted with the “feet” side placed tightly against the inside of the fixture.
    b. J can ballast should be mounted with the PEM Stud side placed tightly against the inside of the fixture.
  2. Lamp holders and conductors: a. Use minimum 4kV Pulse Rated Lamp holder.
    b. Use minimum 600Vrms/4kV Pulse Rated Wire to lamp.
    c. The red lead must be connected to center terminal of lamp.
    d. Do not connect any lamp lead to neutral or ground.
  3. Grounding:
    a. The ballast case and fixture must always be grounded. The grounding helps assure safety, proper lamp starting, and acceptable EMI/RFI performance. Install ballast in accordance with national and local electrical codes.
  4. Auto shut down function including end-of-lamp-life and thermal protection: a. Disconnect power when servicing. Cycle power to reset ballast after auto shutdown.
  5. Control: Do not operate with dimmer or occupancy sensor.
  6. Ifconnectingtheballastinputto208Vor240Vlinewithtwo”hot”leads,besuretowireperNECcode:Re-Mark(re-identify)
    the ballast white neutral wire to another color (i.e. black). Be sure to simultaneously disconnect all ungrounded line conductors per NEC codes (i.e. switch both hot legs).
    More installation considerations are in the QUICKANSWERS section of the Ballast Technology and Specification Guide.

SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - Packaging 2SYLVANIA Quicktronic MH Electronic Metal Halide Systems Installation Guide - Main Product

SYLVANIA, the system solution, METALARC, POWERBALL, and QUICK 60+ are registered trademarks of OSRAM SYLVANIA Inc.
SEE THE WORLD IN A NEW LIGHT is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH.

Performance Guide 

Ballast shall be a metal halide SYLVANIA QUICKTRONIC MH electronic ballast

Specifications

Voltage Range: ±10% of 120-277V
rated line (108-305V)
Input Frequency: 50/60 Hz
Power Factor: >98%
Low THD: <10%
Starting Temp: -22°F (-30°C) min.
Lamp Frequency:
100W Mini-SLIM
200-240Hz Square Wave
20W/39W/70W Mini-Square
165-170Hz Square Wave
UL Listed, Type 1, Outdoor
Suitable for recessed use
20W, 39W, 50W:
85°C Max. Case Temp.
70W, 100W:
90°C Max. Case Temp.
Thermally Protected
FCC 47CFR Part 18 Non-Consumer
Sound Rated A
ANSI C62.41 Cat. A Transient Protection
Remote Mounting capability2
Lamp current crest factor: <1.2

2 Remote Mounting (max. wire length from ballast case to lampholder): Typically 6ft but varies by application. For remote mounting distances up to 15 ft, use #18 AWG minimum 600Vrms/4kV pulse rated wire. Output wires should be
enclosed in 1/2″ metal conduit to minimize EMI (electromagnetic interference). Wire and ground ballast, fixture, conduit & lighting system per NEC (National Electrical Code).

System Life / Warranty 

QUICKTRONIC products are covered by
the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin. Max. Case Temp. Measured at

Tc Point Warranty Period
70W, 100W:
<90°C 3 years
<80°C 5 years
20W, 39W, 50W:
<85°C 3 years
<75°C 5 years

OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com